Item#: 73695
3-Phase 380-500V AC Supply Voltage, Normal Duty: 15 HP 21A, Heavy Duty: 10 HP 14A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R2. H1: 16.11" H2: 14.57" W: 6.1" D: 9.8" Weight: 17.6Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (52 CFM/ 337W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 35A **, ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 0
| |
Item#: 168130
3-Phase 380-500V AC Supply Voltage, Normal Duty: 10 HP 14A, Heavy Duty: 7.5 HP 11A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R2. H1: 16.11" H2: 14.57" W: 6.1" D: 9.8" Weight: 17.6Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (52 CFM/ 232W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 25A **, ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 1
| |
Item#: 90926
3-Phase 380-500V AC Supply Voltage, Normal Duty: 25 HP 34A, Heavy Duty: 20 HP 27A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R3. H1: 18.71" H2: 16.54" W: 6.77" D: 10.28" Weight: 22Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (79 CFM/ 562W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 50A ** , ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 3
| |
Item#: 168149
3-Phase 380-500V AC Supply Voltage, Normal Duty: 200 HP 240A, Heavy Duty: 150 HP 180A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R8. H1: 37.9" H2: 26.82" W: 11.81" D: 15.21" Weight: 154.3Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (324 CFM/ 3300W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 350A **, ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 0
| |
Item#: 168141
3-Phase 380-500V AC Supply Voltage, Normal Duty: 125 HP 156A, Heavy Duty: 100 HP 124A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R7. H1: 34.7" H2: 23.60" W: 11.22" D: 14.37" Weight: 121.3Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (265 CFM/ 1940W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 225A **, ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 3
| |
Item#: 135621
3-Phase 380-500V AC Supply Voltage, Normal Duty: 20 HP 27A, Heavy Duty: 15 HP 21A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R3. H1: 18.71" H2: 16.54" W: 6.77" D: 10.28" Weight: 22Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (79 CFM/ 457W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 40A ** , ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 2
| |
Item#: 161244
3-Phase 380-500V AC Supply Voltage, Normal Duty: 250 HP 302A, Heavy Duty: 200 HP 260A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R9. H1: 37.59" H2: 26.77" W: 14.96" D: 16.27" Weight: 216Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (677 CFM/ 4200W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 400A ** , ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 5
| |
Item#: 168140
3-Phase 380-500V AC Supply Voltage, Normal Duty: 100 HP 124A, Heavy Duty: 75 HP 96A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R6. H1: 28.6" H2: 22.4" W: 9.92" D: 14.09" Weight: 99.2Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (256 CFM/ 1440W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 200A **, ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 3
| |
Item#: 73635
3-Phase 380-500V AC Supply Voltage, Normal Duty: 7.5 HP 11A, Heavy Duty: 5 HP 7.6A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R1. H1: 16.11" H2: 14.57" W: 6.1" D: 8.89" Weight: 13.2Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (26 CFM/ 172W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 20A **, ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 0
| |
Item#: 168138
3-Phase 380-500V AC Supply Voltage, Normal Duty: 60 HP 77A, Heavy Duty: 50 HP 65A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R5. H1: 28.74" H2: 23.46" W: 7.99" D: 10.79" Weight: 50.7Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (165 CFM/ 1120W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 110A **, ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 3
| |
Item#: 168139
3-Phase 380-500V AC Supply Voltage, Normal Duty: 75 HP 96A, Heavy Duty: 60 HP 77A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R6. H1: 28.6" H2: 22.4" W: 9.92" D: 14.09" Weight: 99.2Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (256 CFM/ 1295W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 150A **, ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 4
| |
Item#: 168144
3-Phase 380-500V AC Supply Voltage, Normal Duty: 150 HP 180A, Heavy Duty: 125 HP 156A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R7. H1: 34.7" H2: 23.60" W: 11.22" D: 14.37" Weight: 121.3Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (265 CFM/ 2310W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 300A **, ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 3
| |
Item#: 134473
3-Phase 380-500V AC Supply Voltage, Normal Duty: 30 HP 40A, Heavy Duty: 25 HP 34A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R4. H1: 22.7" H2: 19.3" W: 7.99" D: 10.8" Weight: 40.8Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (79 CFM/ 667W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 60A ** , ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 1
| |
Item#: 168129
3-Phase 380-500V AC Supply Voltage, Normal Duty: 5 HP 7.6A, Heavy Duty: 3 HP 5.2A, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R1. H1: 16.11" H2: 14.57" W: 6.1" D: 8.89" Weight: 13.2Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (26 CFM/ 122W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 15A **, ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 1
| |
Item#: 168152
3-Phase 380-500V AC Supply Voltage, Normal Duty: 350 HP 414A†, Heavy Duty: 300 HP 361A‡, NEMA 1 / IP21, Wall Mount Drive, Frame Size: R9. H1: 37.59" H2: 26.77" W: 14.96" D: 16.27" Weight: 216Lbs, Cabinet Spacing Requirement (7.87 in. Above / 11.81 in. Below), Deratings Required Elevation > 3300ft - Temperature > 104F, Cooling Requirement (677 CFM/ 6000W), ** NOT TO BE USED AS A 3-PHASE POWER SUPPLY ** , **Recommend High Speed Fuses Class T Size 600A ** †At 86F 393A At 104F ‡ 125% Overload 1M every 5., ** Extended Warranty Available w/ Authorized Startup **
Add to Cart for Price,
Co Wide: 2
| | | |